| Item |
Weekly |
Monthly |
Every 2 years |
Period |
| 1 Grit King® Separator |
'Month one only'
External visual inspection for water tightness. |
External visual inspection
for water tightness. |
Drain down, flush out,
and inspect. |
|
| 2 Water Backwash |
None. |
Check filter in Press Reducer. |
|
|
| 3 Air Backwash (alternative
to water) |
None. |
Check inlet filter.
6 Monthly
Replace air filter. |
|
7,000 hours check blades.
Hereafter every 1,000 hours. |
4 Series 3 &
Grit-Cleanse™ Classifier |
As 1 above, plus inspect
for free grit discharge. |
As 1 above, plus inspect
for blockage free grit discharge. |
As 1 above. |
|
| 5 Grit Removal
Pump |
As 1 above. |
As 1 above. |
|
5 year. Monitor flow, if
below 15% of classifier design flow replace the pump
impeller. |
6 Grit Removal
Actuated Valve
(alternative to pump) |
As 1 above. |
As 1 above. |
|
|
| 7 Isolation
Valves |
Generally no
periodic maintenance of the drain down valve, the isolation
valves or the non-return valve is required other than
a half-yearly visual inspection for water tightness
and general operation. |